SI-FEC

From Signal Identification Wiki
Jump to: navigation, search
SI-ARQ - SI-FECForward Error Correction
SI-FECForward Error Correction
SI-FEC.png
Frequencies 3 MHzMegaHertz (MHz) 10^6 Hz3,000,000 HzHertz (Hz), unit of frequency, defined as one cycle per second (1 Hz).
3,000 kHzKiloHertz (kHz) 10^3 Hz
,30 MHzMegaHertz (MHz) 10^6 Hz30,000,000 HzHertz (Hz), unit of frequency, defined as one cycle per second (1 Hz).
30,000 kHzKiloHertz (kHz) 10^3 Hz
3,000 kHzKiloHertz (kHz) 10^3 Hz
MHzMegaHertz (MHz) 10^6 Hz
30,000 kHzKiloHertz (kHz) 10^3 Hz
30 MHzMegaHertz (MHz) 10^6 Hz
Frequency Range MHzMegaHertz (MHz) 10^6 Hz3,000,000 HzHertz (Hz), unit of frequency, defined as one cycle per second (1 Hz).
3,000 kHzKiloHertz (kHz) 10^3 Hz
- 30 MHzMegaHertz (MHz) 10^6 Hz30,000,000 HzHertz (Hz), unit of frequency, defined as one cycle per second (1 Hz).
30,000 kHzKiloHertz (kHz) 10^3 Hz
Mode USBUpper Side Band Modulation (Radio, referring to reception and modulation mode)Universal Serial Bus (Computer, referring to USB Ports and cables)
Modulation FSKFrequency-Shift Keying
ACFAutoCorrelation Function
Bandwidth 280 HzHertz (Hz), unit of frequency, defined as one cycle per second (1 Hz).0.28 kHzKiloHertz (kHz) 10^3 Hz
2.8e-4 MHzMegaHertz (MHz) 10^6 Hz
0.28 kHzKiloHertz (kHz) 10^3 Hz
2.8e-4 MHzMegaHertz (MHz) 10^6 Hz
0.28 kHzKiloHertz (kHz) 10^3 Hz
2.8e-4 MHzMegaHertz (MHz) 10^6 Hz
Location Europe
Short Description SI-FECForward Error Correction, also known as FECForward Error Correction-S, FECForward Error Correction 1000 Simplex, and FECForward Error Correction-1000S, was the FECForward Error Correction variant of SI-ARQAutomatic Repeat reQuestAutomatic Repeat Query, and was only used under extremely poor propagation conditions. SI-FECForward Error Correction was developed by Siemens and was used by Austrian and Indonesian diplomatic services.
I/Q Raw Recording
Audio Sample
SI-FECForward Error Correction, also known as FECForward Error Correction-S, FECForward Error Correction 1000 Simplex, and FECForward Error Correction-1000S, was the FECForward Error Correction variant of SI-ARQ, and was only used under extremely poor propagation conditions. SI-FECForward Error Correction was developed by Siemens and was used by Austrian and Indonesian diplomatic services. No longer used today.

SI-FECForward Error Correction typically uses baudrates of 96, 192 or 200 BdBaud (unit symbol Bd) is the unit for symbol rate or modulation rate in symbols per second. using the ITA-3 alphabet. During idle mode this system is the same as CCIR 242 (ARQ-M2).

Samples[edit]

96 BdBaud (unit symbol Bd) is the unit for symbol rate or modulation rate in symbols per second.:

Decoding Software[edit]

Professional Equipment/Software
  • go2decode
  • go2monitor
  • Hoka Code 300-32
  • Wavecom W-Code
  • Wavecom W-Spectra

Additional Links[edit]